 This article explores the critical process of identifying and integrating external environmental factors into the architectural framework of a comprehensive cleanliness monitor. As urbanization and industrialization accelerate, the demand for precise environmental monitoring systems has surged. The study investigates how various external parameters, primarily particulate matter, volatile organic compounds, carbon dioxide, ambient temperature, and relative humidity, interact and influence the accuracy of integrated sensor arrays. Through empirical testing within a controlled environmental chamber, the research analyzes the cross-sensitivity of these sensors and the modulating effects of climatic variables on pollutant detection. The results demonstrate that failing to account for the synergistic effects of temperature and humidity leads to significant data drift and false cleanliness readings. The article provides a thorough review of contemporary literature and proposes a newly calibrated algorithmic model that dynamically adjusts sensor outputs based on fluctuating external factors, thereby ensuring the high reliability of the developed cleanliness monitor.

References

1.Snyder, E. G., Watkins, T. H., Solomon, P. A., Thoma, E. D., Williams, R. W., Hagler, G. S., & Preuss, P. W. (2013). The changing paradigm of air pollution monitoring. Environmental Science & Technology, 47(20), 11369-11377.

2.Morawska, L., Thai, P. K., Liu, X., Asumadu-Sakyi, A., Ayoko, G., Bartonova, A., & Williams, R. (2018). Applications of low-cost sensing technologies for air quality monitoring and exposure assessment: How far have they gone? Environment International, 116, 286-299.

3.Jayaratne, R., Liu, X., Thai, P., Dunbabin, M., & Morawska, L. (2018). The influence of humidity on the performance of a low-cost air particle mass sensor and the effect of atmospheric fog. Atmospheric Measurement Techniques, 11(8), 4883-4890.

4.Fine, G. F., Cavanagh, L. M., Afonja, A., & Binions, R. (2010). Metal oxide semi-conductor gas sensors in environmental monitoring. Sensors, 10(6), 5469-5502.

5.Castell, N., Dauge, F. R., Schneider, P., Vogt, M., Lerner, U., Fishbain, B., & Bartonova, A. (2017). Can commercial low-cost sensor platforms contribute to air quality monitoring and exposure estimates? Environment International, 99, 293-302.

6.Crilley, L. R., Shaw, M., Pound, R., Kramer, L. J., Price, R., Young, S., & Pope, F. D. (2018). Evaluation of a low-cost optical particle counter. Atmospheric Measurement Techniques, 11(2), 709-720.

7.Spinelle, L., Gerboles, M., Villani, M. G., Aleixandre, M., & Bonavitacola, F. (2015). Field calibration of a cluster of low-cost available sensors for air quality monitoring. Part A: Ozone and nitrogen dioxide. Sensors and Actuators B: Chemical, 215, 249-257.

8.Di Antonio, A., Popoola, O. A., Ouyang, B., Saffell, J., & Jones, R. L. (2018). Developing a relative humidity correction for low-cost sensors measuring ambient particulate matter. Sensors, 18(9), 2790.

9.Maag, B., Zhou, Z., & Thiele, L. (2018). A survey on sensor calibration in air quality monitoring deployments. IEEE Internet of Things Journal, 5(6), 4857-4870.

10.Kumar, P., Morawska, L., Martani, C., Biskos, G., Neophytou, M., Di Sabatino, S., & Britter, R. (2015). The rise of low-cost sensing for managing air pollution in cities. Environment International, 75, 199-205.

Downloads

Published

2026-10-03